XRB160PN688/CT Monoblock®
- Integrated HV Supply, Filament Supply, X-Ray Tube, Beam Port and Control Electronics
- Compact & LIghtweight
- Power Factor Corrected
- Can be Mounted in Any Physical Orientation
- Standard RS-232 Digital Interface
*Note: All specifications are subject to change without notice. Please consult the English PDF version of this datasheet for the most up-to-date revision.
Spellman’s XRB160PN688/CT Monoblock® X-Ray source is designed for OEM applications powering its internal X-Ray tube up to 160kV at 688W. Features like small package size and RS-232 digital interface simplify integrating this unit into your X-Ray system. Proprietary emission control circuitry provides excellent regulation of X-Ray tube current, along with outstanding stability performance.
Typical applications:
- X-Ray Scanning: Food Inspection
- Fill Level Confirmation
- Security Applications
- Specifications
- Downloads
Specifications
(Ref. 128088-001 REV. G)
- X-Ray Characteristics:
- Tube Type:
Glass tube, Tungsten target, Be filter - Focal Spot:
2.5mm x 2.5mm (IEC 60336) - Beam Filter:
1.5mm glass, 9-26mm oil, 0.4mm Al - Beam Geometry:
Asymmetrical fan 93° x 15° - Input Voltage:
230Vac, ±15%, 50/60Hz, 5A max - X-Ray Tube Voltage:
Nominal X-Ray tube voltage is adjustable between 50kV to 160kV - X-Ray Tube Current:
0.25mA to 4.3mA over specified tube voltage range - X-Ray Tube Power:
700W, maximum continuous - Voltage Regulation:
- Line:
±0.1% ±10% - Load:
±0.1% 0.25 to 6mA - Voltage Accuracy:
Voltage measured across the X-Ray tube is within 1% of the programmed value - Voltage Risetime:
Ramp time shall be 500ms nominal, 1 second maximum from 10% to 90% of rated output - Voltage Overshoot:
Within 5% of rated voltage - Voltage Ripple:
1% p-p of rated voltage - Current Regulation:
- Line:
±0.5% ±10% - Load:
±0.5% 0.25 to 4.3mA - Current Accuracy:
Current measured through the X-Ray tube is within 5% of the programmed value - Current Risetime:
500ms nominal, 1 second maximum - Arc Intervention:
4 arcs in 10 seconds = shutdown - Filament Configuration:
Internal high frequency AC filament drive with closed loop filament emission control - Digital Interface:
RS-232 interface. - Control Software:
A demo GUI for engineering evaluations will be provided for the RS-232 digital interface upon request. - Interlock Signals:
A hardware interlock function is provided - Operating Temperature:
5°C to +40°C - Storage Temperature:
-25°C to +65°C - Humidity:
10% to 90% relative humidity, non-condensing - Cooling:
Heat exchanger w/fan and oil pump, powered from AC - Input Line Connector:
5 pin Molex 26-60-4050 - Cooling Power Connector:
4 pin Tyco 206061-1 - Digital Interface Connector:
9 pin D connector, female - Grounding Point:
M5 ground stud provided on chassis - Dimensions:
See drawing - Weight:
140lbs ±10lbs (64kg ±4.5kg) - Orientation:
Can be mounted in any orientation. - X-Ray Leakage:
Less than 300uR/hr at a distance of 10cm from all surfaces - Special Features:
Stationary or rotating CT application up to 100rpm at a maximum radius 20.25˝ (514mm).