MNX Series
- 50kV at 50 or 75 Watt Max
- 65kV at 65 Watt Max
- Adjustable Integrated Filament Supply
- Local and Remote Emission Control
- CE Marked, UL Recognized
Certifications & Compliance
50-75W Industrial X-Ray Generators
The MNX Series is the result of Spellman’s exceptional high voltage packaging and surface mount fabrication techniques coupled with proprietary encapsulation technology producing this ultra-compact X-Ray generator module. The MNX powers grounded cathode X-Ray tubes from a variety of well-known manufacturers, featuring a 0 to 50kV/65kV high voltage output @ 2mA limited to 50, 65 or 75 Watts. The MNX uses closed loop filament control circuitry providing highly regulated beam current. The ground referenced low noise dc filament supply operates between 0.3 and 3.5 amps. Offering tight regulation, high stability and low ripple, the MNX provides users local and remote analog control to set beam voltage, emission current and filament current limit.
The MNX is designed to run a variety of tubes from industry leading manufacturers. Contact Spellman sales to determine if the X-Ray tube of interest can be powered by the MNX.
- Specifications
- Models
- How to Order
Specifications
(Ref. 128023-001 REV. AE)
- Input Voltage:
+24Vdc ±10%, for 50W or 75W units
+24Vdc ±1V, for 65kV @ 65W unit - Input Current:
MNX50P50: 4.0 amps, maximum
MNX50P75: 6.0 amps, maximum
MNX65P65: 5.0 amps, maximum
GB Option: 1.0 amp additional, maximum - Output:0 to 50kV at 0 to 2mA, limited to a maximum of 50 watts or
75 Watts.
0-65kV at 2mA limited to 65 Watts. - DC Filament Supply:
Current: 3.5A, adjustable limit
Voltage: 5.0 volt limit
Voltage Regulation: Load: 0.01% of output voltage no load to full load. Line: ±0.01% for ±10% change in input voltage.
Current Regulation: Load: 0.01% of output current from 0 to rated voltage. Line: ±0.01% for ±10% change in input voltage.
Ripple: 0.1% p-p of maximum rated output voltage, 50kV units (50/75W) 0.1% rms maximum rated output voltage, 65kV units (65W) - Temperature Coefficient:
0.01% per °C, voltage and current.
Stability: 0.05% per 8 hours after 1/2 hour warm-up. - Dimensions:
50kV Unit:
5.00”H x 2.87”W x 8”D (127.00mm x 72.90mm x 203.25mm)
65kV Unit:
5.00”H x 2.87”W x 9”D (127.00mm x 72.90mm x 228.65mm)
XCC Option:
5.00”H x 2.87”W x 9”D (50/75W units only) (127.00mm x 72.90mm x 228.65mm) - Weight: 6.5 lbs. (2.9kg)
- Regulatory Approvals:
Compliant to EEC EMC Directive. Compliant to EEC Low Voltage Directive. UL/CUL recognized, File E227588; MNX65P65 is not UL/CUL recognized. RoHS Compliant.
Models
MNX SELECTION TABLE
| Model | Output Voltage | Output Power |
|---|---|---|
| MNX50P50 | 50kV | 50W |
| MNX65P65 | 65kV | 65W |
| MNX50P75 | 50kV | 75W |
| Option | Description |
|---|---|
| XCC | XRM Compatible HV Cable (50kV only) |
| 5VPM | 0 to 5 Volt Programming and Monitor Scaling |
| 5302 | Mammoflex HV cable for MNX |
| 2001 | Mammoflex HV cable for MNX w/XCC option |
How to Order
| How to Order: |
|---|
Sample model number: |
| Options are added to the model number as follows: MNX50P50/XCC |
Typical Applications:
- Analytical X-Ray
- X-Ray Fluorescence
- X-Ray diffraction
- Non-destructive testing
- Thickness Gauging
- Tube testing
Service Solution Brochure
Spellman Repair Centers, Extended Warranty Programs, Preventative Maintenance Programs, Calibration Services and more.
Download2026 High Voltage Reference Manual
We compiled all of our useful FAQ’s, application notes, articles, technical papers and three glossaries into a single handy reference guide.
DownloadSubscribe to our high voltage newsletter
Subscribe to our high voltage newsletter, published quarterly with relevant information on high voltage power supply technology and applications.