Back
Browse Products By:
APPLICATIONS
Back
Browse Products By Application
View All Applications

DXB Series

  • Bipolar Outputs in a Single Unit
  • Compact & Lightweight
  • Models from 40kV to 320kV, 300W, 600W and 1200W
  • Universal Input, Power Factor Corrected
  • USB, Ethernet and RS-232 Standard Interfaces
  • CE Compliant, UL Recognized

Certifications & Compliance

Get a Quote

Industrial X-Ray Generators DXB Series 300-1200W

Spellman’s new DXB Series of bipolar X-Ray generator modules are designed for OEM applications up to 320kV (±160kV) at 1200 watts. Its universal input, small package size and choice of three standard digital interfaces simplifies integrating the DXB into your X-Ray analysis system. DSP based emission control circuitry provides excellent regulation of emission current, along with outstanding stability performance.

  • Specifications
  • Models

Specifications

(Ref. 128100-001 REV. N)

  • Input Voltage:
    Power factor corrected input:
    100-240Vac, ±10% (90-264Vac):
    47-63Hz @ 5.7A for 300 watt units

    200-240Vac, ±10% (180-264Vac):
    47-63Hz @ 4.8A for 600 watt units
    47-63Hz @ 8.0A for 1200 watt units
  • Output Voltage:
    7 models: 40kV, 60kV, 80kV, 100kV, 120kV, 140kV and 320kV
  • Output Polarity:
    ± bipolar output, filament referenced to negative output
  • Power:
    3 power ranges available—300 watts, 600 watts and 1200 watts Other power levels available on special order.
  • Output Voltage Regulation:
    ≤0.01% of rated output voltage over specified input voltage range ≤0.01% of rated output voltage for a full load change
  • Emission Current Regulation:
    ≤0.01% of rated output current over specified input voltage range
    ≤0.01% of rated output current for a change from 30% to 100% of rated output voltage
    Filament is disabled when kV is <30% of full scale output
  • Ripple:
    ≤1%rms at >20 kHz, 0.1%rms below 20 kHz
    Stability:
    ≤25ppm/hr after a 2 hour warm up
    Temperature Coefficient:
    ≤50ppm per degree C
  • Filament Configuration: Closed loop emission control regulates filament setting to provide desired X-Ray tube emission current.
    Floating Filament (ac output referenced to negative output voltage).
    Output
    0-5 amps at a compliance of 10 volts, maximum
  • Cooling:
    Forced air
  • Weight: 40-140kV: 26 pounds (11.8kg)
    320kV: 150 pounds (68kg)
  • Dimensions:
    40-140kV:
    4.75˝ H X 12˝ W X 12˝ D (120.65mm x 304.8mm x 304.8mm)
    320kV:
    10.5˝ H X 19.0˝ W X 21.5˝ D (266.7mm x 482.6mm x 546.1mm)
  • Regulatory Approvals:
    Compliant to EEC EMC Directive. Compliant to EEC Low Voltage Directive. UL/CUL recognized, File E227588. RoHS Compliant. DXB320PN1200 is not UL recognized.

Models

DXB SELECTION TABLE— 300W, 600W, 1200W

300 Watt600 Watt1200 Watt
kVmAModelmAModelmAModel
407.50DXB40PN30015.0DXB40PN60030.0DXB40PN1200
505.00DXB60PN30010.0DXB60PN60020.0DXB60PN1200
803.75DXB80PN3007.50DXB80PN60015.0DXB80PN1200
1003.00DXB100PN3006.00DXB100PN60012.0DXB100PN1200
1202.50DXB120PN3005.00DXB120PN60010.0DXB120PN1200
1402.14DXB140PN3004.28DXB140PN6008.57DXB140PN1200
 320 Not Available Not Available 3.75 DXB320PN1200

Typical applications:

  • Plastics Sorting
  • Crystal Inspection
  • Plating Measurement
  • Thickness Gauging
  • Food Inspection
  • Mineral Analysis
  • X-Ray Fluorescence
  • X-Ray Diffraction
  • Cargo Screening