Back
Browse Products By:
APPLICATIONS
Back
Browse Products By Application
View All Applications

XRB160PN480/2 Monoblock®

  • Integrated HV Supply, Filament Supply, X-Ray Tube, Beam Port and Control Electronics
  • Compact & LIghtweight
  • Universal Input, Power Factor Corrected
  • Can be Mounted in Any Physical Orientation
  • Analog Control Interface and Standard RS-232 Digital Interface
Get a Quote

160kV, 480W X-Ray Source

Spellman’s XRB160PN480/2 Monoblock® X-Ray source is designed for OEM applications powering its internal X-Ray tube up to 160kV at 480W. Features like universal input, small package size and a standard analog and RS-232 digital interface simplify integrating this Monoblock® into your X-Ray system. Standard models are available with fan shaped beam geometry. Proprietary emission control circuitry provides excellent regulation of X-Ray tube current, along with outstanding stability performance.

Typical applications:

  • X-Ray Scanning: Food Inspection
  • Fill Level Confirmation
  • Security Applications
  • Specifications
  • Downloads

Specifications

(Ref. 128087-001 REV. J)

  • X-Ray Characteristics:
  • Tube Type:
    Glass tube, Tungsten target, Be filter
  • Focal Spot:
    0.8mm x 0.8mm (IEC336)
  • Beam Filter:
    1mm curved window
  • Beam Geometry:
    Asymmetrical fan 80° x 10° ±2°
  • Input Voltage:
    100-240Vac ±10%, 50/60Hz, 6.5A max; 12Vdc @ 5A
  • X-Ray Tube Voltage:
    Nominal X-Ray tube voltage is adjustable between
    80kV to 160kV
  • X-Ray Tube Current:
    0.25mA to 3mA over specified tube voltage range
  • X-Ray Tube Power:
    500W, maximum
  • Voltage Regulation:
  • Line:
    ±0.1% for a ±10% input line change of nominal input line voltage
  • Load:
    ±0.1% for a 0.3mA to 3mA load change
  • Voltage Accuracy:
    Voltage measured across the X-Ray tube is within ±1% of the programmed value
  • Voltage Risetime:
    Ramp time shall be <1 second from 10% to 90% of rated output
  • Voltage Overshoot:
    Within 5% of rated voltage in <10ms
  • Voltage Ripple:
    0.1% p p of rated voltage @ ≤1kHz
  • Current Regulation:
  • Line:
    ±0.1% for a ±10% input line change of nominal input line voltage
  • Load:
    ±0.5% @ 80-160kV, 0.3mA to 3mA
  • Current Accuracy:
    Current measured through the X-Ray tube is within ±1% of the programmed value
  • Current Risetime:
    <1 second from 10% to 90% of rated output
  • Arc Intervention:
    4 arcs in 10 seconds with a 200ms quench = Shutdown
  • Filament Configuration:
    Internal high frequency AC filament drive with closed loop filament emission control