SpellmanHV V6 Compact 30W Precision High Voltage Power Supplies (Featured Image)

Precision V6 Series

  • Precision High Voltage compact Models up to 30kV
  • High Stability, Low Ripple and Noise
  • Local and Remote Programming and Monitoring
  • RoHS Compliant

*Note: All specifications are subject to change without notice. Please consult the English PDF version of this datasheet for the most up-to-date revision.

 Two Year Extended Warranty Logo CE RU Marking RoHs Compliant logo

Compact 30W Precision High Voltage Power Supplies

The precision high voltage V6 Series is a family of regulated, fixed output  polarity modular precision high voltage power supplies which provide exceptional performance and value in many applications.  The V6 Series precision high voltage power units are fully enclosed and designed for system or bench top operation. A wide range of output voltages, up to 30kV is available. The output voltage is controlled locally by an internal multi-turn potentiometer. Remote analog voltage or resistance programming capability is included in all models. Analog monitor outputs are also included for remote monitoring of both the high voltage and current outputs.

The typical applications which the V6 Series precision high voltage power modules are used in are:

  • Spectrometers
  • CRT Testing
  • Detectors
  • E Beam Systems
  • General Laboratory Usage

Specifications

(Ref. 128069-001 REV. L)

Input Voltage:

AC Model: 100-240Vac, ±10%; 50/60 Hertz; 1 amp 
DC Model: 24Vdc ±10%, 2 Amps

Voltage Regulation:

Line: ±0.005% of maximum 90-240Vac input line change.
±0.005% of maximum ±10%Vdc input line change Load: ±0.01% of maximum for 0 to maximum rated output current change

Current Regulation:

Line: ±0.05% of maximum current for 90-240Vac input line change.
0.05% of maximum current for ±10% Vdc input change Load: 0.2% of maximum current for 0 to maximum rated output voltage change

Ripple:

See “model selection” table

Temperature Coefficient:

≤ 50ppm/°C

Stability:

≤ 0.01%/hour, 0.02% per 8 hours after a 1/2 hour warm up

Operating Temperature:

0°C to +50°C

Storage Temperature:

-40°C to +85°C

Humidity:

20% to 85%RH, non-condensing 

Local Control:

Internal multi-turn potentiometer for 0 to maximum output voltage (±0.2%)

Remote Programming:

0 to +5Vdc analog input signal proportional to 0 to maxi­mum rated output. Accuracy is ±(0.1% of setting +0.1% of maximum). The programming input impedance is 20 megohms. 

Voltage Monitor:

0 to +5V proportional to 0 to maximum output voltage. Accuracy is ±(0.1% of reading +0.1% of maximum).  The monitor impedance is 10 kilohms.

Current Monitor:

0 to +5V proportional to 0 to maximum output voltage. Accuracy is ±(2.0% of reading +1.0% of maximum).  The monitor impedance is 10 kilohms.

Enable:

Remote interlock enables (low) disables internally (high) the high voltage output. Signal is normally high and supply will default to a disabled condition.

Current Limit:

All units provide short circuit current limiting to less than 110% of the maximum rated output current. Supply is self restoring upon removal of cause limit condition. 

Arc/Short Circuit:

Short circuit and arc protected; self restoring.

Cooling:

Convection cooled

Output Connector: 

Models up to and including 5kV use a Spellman P/N JAC high voltage connector.  The required mating connector is a Spellman P/N 105808-384, which is provided. The 10kV through 30kV units use a Spellman P/N JGP high volt­age connector (Alden 8101). All 10 through 30kV units are 1 provided with mating connectors assembled to 2.0 meters 2 of high voltage cable.

Dimensions:

AC Model: 3.05. W X 5.1. H X 7.06. D (77mm X 132mm X 179mm)

DC Model: 2.32. W X 5.1. H X 7.06. D (59mm X 132mm X 179mm)

Weight:

AC Model: 4.5 pounds (2.0kg)

DC Model: 3.75 pounds (1.7kg)

Regulatory Approvals:

Compliant to EEC EMC Directive. Compliant to EEC Low Voltage Directive. UL/CUL recognized, File E227588. RoHS Compliant.

OPTIONS

RS - RS-232 Interface

V6A MODEL SELECTION TABLE

V6 AC Series Voltage Current Ripple
V6A1*30 0 to 1kV 0 to 30mA 75mV
V6A1.5*30 0 to 1.5kV 0 to 20mA 75mV
V6A3*30 0 to 3kV 0 to 10mA 120mV
V6A5*30 0 to 5kV 0 to 6mA 150mV
V6A10*30 0 to 10kV 0 to 3mA 400mV
V6A15*30 0 to 15kV 0 to 2mA 900mV
V6A20*30 0 to 20kV 0 to 1.5mA 1.0V
V6A30*30 0 to 30kV 0 to 1mA 1.8V

*Specify “P” for positive polarity or “N” for negative polarity 

V6D MODEL SELECTION TABLE

V6 DC Series Voltage Current Ripple
V6D1*30 0 to 1kV 0 to 30mA 75mV
V6D1.5*30 0 to 1.5kV 0 to 20mA 75mV
V6D3*30 0 to 3kV 0 to 10mA 120mV
V6D5*30 0 to 5kV 0 to 6mA 150mV
V6D10*30 0 to 10kV 0 to 3mA 400mV
V6D15*30 0 to 15kV 0 to 2mA 900mV
V6D20*30 0 to 20kV 0 to 1.5mA 1.0V
V6D30*30 0 to 30kV 0 to 1mA 1.8V

*Specify “P” for positive polarity or “N” for negative polarity

V6A ANALOG/DIGITAL INTERFACE— J1 15 PIN FEMALE D CONNECTOR

Pin Signal Signal Parameters
1 Local Voltage Program Multi-turn front panel potentiometer
2 TX Out (optional) RS232 Receive Data
3 RX In (optional) RS232 Transmit Data
4 Voltage Program Input 0 to 5V=0 to 100% Rated Output, Zin=20MΩ
5 Signal Ground RS232 Ground (optional)
6 Signal Ground Ground
7 +5V Reference Out +5V @ 1mA Max.
8 HV Enable Input Active Low to Enable the HV
9 Current Program Input 0 to 5V=0 to 100% Rated Output, Zin=20MΩ
10 Current Monitor 0 to 5V=0 to 100% Rated Output, Zout=10kΩ
11 Voltage Monitor 0 to 5V=0 to 100% Rated Output, Zout=10kΩ
12 HV Enable Output Active Low HV is Enabled
13 Signal Ground Ground
14 N/C No Connection
15 N/C No Connection

V6D ANALOG/DIGITAL INTERFACE— J1 15 PIN FEMALE D CONNECTOR

Pin Signal Signal Parameters
1 Local Voltage Program Multi-turn front panel potentiometer
2 TX Out (optional) RS232 Receive Data
3 RX In (optional) RS232 Transmit Data
4 Voltage Program Input 0 to 5V=0 to 100% Rated Output, Zin=20MΩ
5 Signal Ground RS232 Ground (optional)
6 Signal Ground Ground
7 +5V Reference Out +5V @ 1mA Max
8 HV Enable Input Active Low to Enable the HV
9 Current Program Input 0 to 5V=0 to 100% Rated Output, Zin=20MΩ
10 Current Monitor 0 to 5V=0 to 100% Rated Output, Zout=10kΩ
11 Voltage Monitor 0 to 5V=0 to 100% Rated Output, Zout=10kΩ
12 HV Enable Output Active Low HV is Enabled
13 +24V Return Input Voltage Return
14 +24Vdc Input Input Voltage 24V±10%, 2A
15 +24Vdc Input Input Voltage 24V±10%, 2A

Tables & Diagrams