XRB200PN400/2 Monoblock®

  • 200kV and 400W
  • X-Ray Tube Current: 0.5mA to 2.0mA @ 200kV
  • Symmetrical fan beam of 85° X 4°, ±1%
  • Power factor corrected input to 0.98
  • 100Vac to 240Vac, ±10%
  • Logging and Firmware Controlled X-Ray Tube Seasoning

*Note: All specifications are subject to change without notice. Please consult the English PDF version of this datasheet for the most up-to-date revision.

견적 받기

Spellman’s XRB200PN400/2 is an integrated X-Ray source operating up to 200kV and 400W, providing OEM users a compact plug-and-play Monoblock® for critical inspection and screening applications. The unit incorporates a 15° angle stationary anode X-Ray tube offering a symmetrical fan beam of 85° X 4°. Proprietary emission control circuitry provides excellent regulation of X-Ray tube current, with industry leading dose stability and image quality. This compact model comes with standard analog and RS-232 digital control. Spellman can provide customized versions of this platform for specific OEM system requirements.

TYPICAL APPLICATIONS

Aviation Security Screening: Checked Baggage/EDS Vehicle Inspection, Cargo Inspection, General NDT

  • 사양
  • 다운로드

사양

(Ref. 128085-001 REV. B)

  • X-Ray Characteristics:
  • Tube Type:
    Stationary Anode, tungsten target
  • Focal Spot:
    0.8 x 0.8mm nominal (IEC60336)
  • Beam Filter:
    Glass 2.1mm, maximum. Oil 18mm.
  • Beam Geometry:
    Symmetrical fan of 85° X 4°, ±1%
  • Anode Angle:
    15°
  • Input Voltage:
    Power factor corrected input to 0.98. 100Vac to 240Vac, ±10%, 50/60 Hertz. 6 Amps, maximum
  • X-Ray Tube Voltage:
    Nominal X-Ray tube voltage is adjustable between 100kV to 200kV
  • Voltage Accuracy:
    The high voltage measured at the X-ray tube will be within ±1% of the selected value.
  • Voltage Ripple:
    Ripple will be 1% of maximum rated voltage for frequencies ≤1kHz.
  • Voltage Regulation:
    < ±0.1% for ±10% of nominal input line change
    < ±0.1% for 0.5mA to 2mA load change
  • Voltage Overshoot:
    kV overshoot will return within 5% of full voltage in less than 100ms.
  • Risetime:
    The voltage and current risetime is controlled by a ramping circuit. Ramp time is less than 1.0 second from 10% to 90% of output voltage and current.
  • X-Ray Tube Current:
    0.5mA to 2.0mA @ 200kV, 400 watts maximum
  • Current Accuracy:
    <±1% of the selected value.
  • Current Regulation:
    <0.5% at 100 - 200 kV, 0.5mA to 2.0mA
  • Arc Intervention:
    Unit will detect a single arc but HV will not shut down. If multiple arcs occur (4 in 10 seconds) then the unit will shut down.
  • Filament Configuration:
    Isolated high frequency AC filament drive operated in current mode with closed loop thermionic filament emission control.
  • Digital Interface:
    The RS-232 and Ethernet interfaces allow for programming of the voltage, current and X-Ray Enable. Provides monitoring for voltage, current and oil temperature. Tolerance is 3%.
  • Control Software:
    A demo GUI is available for engineering evaluation.
  • Operating Temperature:
    0°C to +40°C
  • Storage Temperature:
    -40°C to +70°C
  • Humidity:
    10% to 95% relative humidity, non-condensing.
  • Cooling:
    Heat exchanger with fan and oil pump. Customer provided +24Vdc @ 3A is required. In certain situations, external cooling fans of 250CFM may be required to maintain tank/oil temperature below 55°C.
  • Input Line Connector:
    3 pin Phoenix Contact, p/n 1829167. Mating connector provided with unit.