XRBHR Monoblock® Series
- Compact & Lightweight
- Universal Input, Power Factor Corrected
- Can be Mounted in Any Physical Orientation
- Analog Monitoring Interface, Standard RS-232 Digital Interface and Ethernet
- Data Logging and Firmware Controlled X-Ray Tube Seasoning
Certifications & Compliance
100W, 210W, 350W and 500W X-Ray Source
Spellman’s XRBHR (high reliability) Series of Monoblock® X-Ray sources are designed for OEM applications powering their internal Bipolar X-Ray tube at 80kV and 100kV at power levels of 100W, 210W, 350W and 500W. Features such as universal input, compact package size and a standard RS-232 digital interface simplify integration of any XRBHR model into your X-Ray system. Each XRBHR model is available with fan shaped (standard) or cone shaped (optional) beam geometries. Proprietary emission control circuitry provides excellent regulation of X-Ray tube current, along with outstanding stability performance. The XRBHR Series is designed for long field life and comes with a3 year warranty.
TYPICAL APPLICATIONS
Food Inspection Systems, Fill Level Confirmation Systems, Security Scanning Systems, Industrial NDT Systems, Thickness/Plating Measurement Systems
- Specifications
- Models
- How to Order
Specifications
(Ref. 128132-001 REV. W)
- Options:
CB
Cone Beam
.5mm
.5mm focal spot X-Ray tube
ST-TE
See Cable Options
RA-SE
See Cable Options
RA-TE
See Cable Options - X-Ray Characteristics:
- Focal Spot:
0.8mm (IEC 336) standard
0.5mm (IEC 336) optional - Beam Filter:
- Ultem:
1.50mm ±0.15mm - Oil:
9.0mm ±0.25mm - Glass:
1.7mm ±0.2mm - Be:
0.8mm - Beam Geometry:
- Fan:
Standard. The beam angular coverage will be 80° with the beam plane perpendicular to the X-Ray tube axis and 12° wide (with a 2° tolerance) - Cone:
Optional. 40° cone beam (with a 2° tolerance) - Input Voltage:
100-240Vac, ±10%, 50/60 Hertz, .98 power factor - Input Current:
100W @ 2A
210W @ 4A
350W @ 6A
500W @ 8A - X-Ray Tube Voltage:
See table. Minimum kV for emission current 35kV - X-Ray Tube Current:
See table. Minimum emission current 150uA - X-Ray Tube Power:
See table - Voltage Regulation:
- Line:
±0.05% of maximum output voltage over a ±10% change of nominal input line voltage - Load:
±0.1% of maximum rated voltage for 150uA to full rated load change - Voltage accuracy:
Voltage measured across the X-Ray tube is within ±2% of the programmed value - Voltage Risetime:
Standard ramp time shall be <500ms from 10% to 90% of maximum rated output voltage - Voltage Ripple:
0.5% peak to peak of maximum voltage for frequencies ≤1kHz
Emission Current Parameters - Current Regulation:
- Line:
±0.05% of rated output current over a ±10% change of nominal input line voltage - Load:
±0.1% of rated output current for a change from 50% to 100% of rated output voltage - Current Accuracy:
Current measured through the X-Ray tube is within ±2% of the programmed value - Current Risetime:
- Standard:
Ramp time shall be <500ms from 10% to 90% of maximum rated current - Arc Intervention:
4 arcs in 10 seconds with a 100ms quench/100ms re-ramp = Shutdown - Filament Configuration:
Internal AC filament drive with closed loop filament emission control