XRB160PN192

  • Integrated HV Supply, Filament Supply, X-Ray Tube, Beam Port and Control Electronics
  • Compact & Lightweight
  • Universal Input, Power Factor Corrected
  • Can be Mounted in Any Physical Orientation
  • Analog Monitoring and Standard RS-232 Digital Interface

*Note: All specifications are subject to change without notice. Please consult the English PDF version of this datasheet for the most up-to-date revision.

XRB160PN192 Monoblock® Industrial X-Ray Generators

Spellman’s XRB160PN192 Monoblock® X-Ray source is designed for OEM applications powering its internal X-Ray tube up to 160kV at 192W. Features like universal input, small package size and a standard analog and RS-232 digital interface simplify integrating this Monoblock® into your X-Ray system. Standard models are available with fan shaped beam geometry. Proprietary emission control circuitry provides excellent regulation of X-Ray tube current, along with outstanding stability performance.

TYPICAL APPLICATIONS

X-Ray Scanning: Plating Measurement, Food Inspection, Fill Level Confirmation and Security Applications

Технические характеристики

(Ref. 128085-001 REV. M)

X-Ray Characteristics:

Tube Type:  Glass tube, Tungsten target, Be filter

Focal Spot:  0.8mm x 0.8mm

Beam Filter:  0.016˝ thick 6061 Al

Beam Geometry: Asymmetrical fan 80° x 10° ±2° 

Input Voltage:

100-240Vac ±10%, 50/60Hz, 5A maximum

X-Ray Tube Voltage:

0.1mA to 1.2mA, 192W maximum over specified tube voltage range

X-Ray Tube Power:

192W maximum continuous

Voltage Regulation:

Line: ±0.1% for a ±10% input line change of nominal input line voltage
Load: ±0.1% for a 0.1mA to 1.2mA load change

Voltage Accuracy:

Voltage measured across the X-Ray tube is within ±2% of the programmed value

Voltage Risetime:

Ramp time shall be <200ms from 10% to 90% of rated output

Voltage Overshoot:

Within 5% of rated voltage in <10ms

Voltage Ripple:

1% p p of rated voltage @ ≤1kHz

Current Regulation:

Line: ±0.1% for a ±10% input line change of nominal input line voltage
Load: 0.5% @ 80-160kV, 0.1mA to 1.2mA

Current Accuracy:

Current measured through the X-Ray tube is within ±2% of the programmed value

Current Risetime:

<200ms from 10% to 90% of rated output

Arc Intervention:

4 arcs in 10 seconds with a 200ms quench = Shutdown

Filament Configuration:

Internal high frequency AC filament drive with closed loop filament emission control

Analog Interface:

0 to 10Vdc ground referenced signals

Digital Interface:

RS-232 interface

Control Software:

A demo GUI for engineering evaluations will be provided for the RS-232 digital interface upon request.

Interlock Signals:

A hardware interlock function is provided

Operating Temperature:

0°C to +40°C

Storage Temperature:

-40°C to +70°C

Humidity:

10% to 95% relative humidity, non-condensing

Cooling:

Natural convection augmented by customer provided 250cfm cooling fans for 192W operation

Input Line Connector:

6 pin Molex 26-60-4060

Analog Interface Connector:

7 pin Molex 26-60-5070

Digital Interface Connector:

9 pin D connector, female

Grounding Point:

8-32 ground stud provided on chassi

Dimensions:

18" x 13.5" x 7.63" (458mm x 343mm x 193.80mm) 

Weight:

90lbs (40.5kg) 

Orientation:

Can be mounted in any orientation.

X-Ray Leakage:

Not to be greater than 0.5mR/hr at 5cm outside the external surface 

Regulatory Approvals:

Compliant to EEC EMC Directive (external EMC filter required). Compliant to EEC Low Voltage Directive. UL/CUL recognized file E235530.

 

AC INPUT POWER J1 6 PIN CONNECTOR

Pin Signal Parameters
1 Line Line
2 Removed N/C
3 Neutral Neutral
Removed  N/C 
Spare  N/C 
Spare  N/C 

 

TERFACE— J7 7 PIN MOLEX CONNECTOR 

Pin Signal Parameters
1 Ex Gate Low = X-Ray OFF, +12Vdc = X-Ray ON
2 Signal Ground Ground
3 N/C  No Connection
4 kV Monitor 0-9 Vdc = 0 to 100% rated output
5 Signal Ground Ground
6 mA Monitor 0 to 9Vdc = 0 to 100% rated output
Fault Open collector, 35V @ 10mA max, High = No Fault

 

LED INDICATORS

Pin Signal Parameters
LED 1 OV High kV occurs
LED 2 UV Low kV occurs
LED 3 UC Low mA occurs
LED 4 OC High mA occurs
LED 5 ARC FLT Arc fault occurs
LED 6 OT Over temperature occurs
LED 7 X-RAY ON X-Rays are enabled
LED 8 PWR Power is ON

 

Таблицы и диаграммы

 DIMENSIONS: in.[mm

FRONT VIEW

XRB160PN192 X-Ray generator front view 

TOP VIEW

XRB160PN192 X-Ray generator top view 

BACK VIEW

 XRB160PN192 X-Ray generator back view

SIDE VIEW

XRB160PN192 X-Ray generator side view