CCM Series
- Compact & Lightweight Package
- Power Factor Corrected Input
- Low Cost Modular OEM Platform
- Rugged IGBT Inverter Design
- Auxiliary +24Vdc @ 2.2 Amp Output Provided
*Note: All specifications are subject to change without notice. Please consult the English PDF version of this datasheet for the most up-to-date revision.
4kV Capacitor Charging Module
Spellman’s CCM capacitor charging module is designed to provide 3100 joules per second at an output voltage up to 4000 Volts. With a power density of 6.6 watts per cubic inch, the CCM packs more than 30% more power into the same volume when compared to other commercially available units. The power factor corrected AC input, small package size and comprehensive analog interface simplifies integrating the CCM into your OEM system design. Available in either positive or negative polarity, the CCM is fully arc, open and short circuit protected.
Typical applications:
- UV light sources for curing and sterilization
- Industrial and medical laser applications
- ICP-MS applications
사양
(Ref. 128054-001 REV. R)
Input Voltage:
Power factor corrected input ≥0.98
180-264Vac @ 20.3A, 47-63Hz, fused via externally
accessible fuses
Efficiency:
>85%
Output Power:
3100 Joules per second, average
Output Voltage:
4000 Volts, maximum
Output Polarity:
Positive
Pulse to Pulse Repeatability:
±0.6% up to 120 Hertz
Temperature Coefficient:
≤ 100ppm per degree C
Fault Diagnostic System:
Over Temperature, Over Voltage and Open Load sensing
Environmental:
Temperature Range:
Operating: 0°C to 40°C
Storage: -40°C to 85°C
Humidity:
10% to 90% RH, non-condensing
Cooling:
Forced air
Ground Stud:
M6 X10mm, M6 nut supplied
Input Line Connector:
2 position Phoenix HDFK4 connector
HV Output Connector:
Kings KV-79-15, Bulkhead mounted
+24Vdc Output Connector:
AMP #1-350942-0
Dimensions:
5.81. H X 5.8. W X 14. D (148mm x 147mm x 356mm)
Weight:
14.5lb. (6.6kgs)
Regulatory Approvals:
Compliant to the EEC EMC directive. Compliant to EEC low voltage directive.
AUXILIARY +24VDC CONNECTOR J2 POSITION AMP CONNECTOR
Pin | Signal | Signal Parameters |
---|---|---|
1 | +24Vdc | +24Vdc @ 2.2 amps |
2 | Ground | Ground |
CCM ANALOG INTERFACE— J1 15 PIN FEMALE D CONNECTOR
Pin | Signal | Signal Parameters |
---|---|---|
1 | Inhibit | Ground = HV ON, High = HV OFF |
2 | Temperature Fault | Ground = No Fault, +15Vdc = Fault +15Vdc through 6.8kΩ |
3 | General Fault | Ground = No Fault, +15Vdc = Fault +15Vdc through 6.8kΩ |
4 | HV ON Indicator | Ground = HV ON, +15Vdc = HV OFF +15Vdc through 6.8kΩ |
5 | Voltage Program | 0 to 10Vdc = 0 to 100% Rated Output |
6 | Open Circuit Detector | Ground = Open Circuit, +15Vdc = OK +15Vdc through 6.8kΩ |
7 | Peak Voltage Monitor | 0 to 10Vdc = 0 to 100% Rated Output held for 10 seconds at peak level |
8 | Voltage Monitor | 0 to 10Vdc = 0 to 100% Rated Output, Instantaneous output |
9 | +15Vdc Output | +15Vdc @ 150ma output, maximum |
10 | n/c | n/c |
11 | +15Vdc Output | +15Vdc @ 150ma output, maximum |
12 | +15Vdc Output | +15Vdc @ 150ma output, maximum |
13 | End of charge Indicator | Ground = End of Charge, High Impedance = Charging |
14 | Ground | Ground |
15 | Ground | Ground |
How to Order: |
---|
Standard: PART NO.: CCM4P3100 |
테이블 및 다이어그램
DIMENSIONS: in.[mm]
FRONT VIEW
TOP VIEW
BACK VIEW
Frequently Asked Questions
What Is a Safe Level of High Voltage?
Where Can I Obtain Information on High Voltage Safety Practices?
How Should I Ground Your Supply?
Why Do I Have to Fill Out a Capacitor Charging Questionnaire If I’m Going to Use Your Power Supply for Capacitor Charging?