XRB80PN320 Monoblock® Industrial X-Ray Generators
- Integrated HV Supply, Filament Supply, X-Ray Tube, Beam Port and Control Electronics
- Compact & Lightweight
- Can be Mounted in Any Physical Orientation
- Standard RS-232 Digital Interface
*Note: All specifications are subject to change without notice. Please consult the English PDF version of this datasheet for the most up-to-date revision.
80kV, 320W X-Ray Source
Spellman’s XRB80PN320 Monoblock® X-Ray source is designed for OEM applications powering its internal X-Ray tube up to 80kV at 320W. Features like small package size and RS-232 digital interface simplify integrating this Monoblock® into your X-Ray system. Standard models are available with fan shaped beam geometry. Proprietary emission control circuitry provides excellent regulation of X-Ray tube current, along with outstanding stability performance.
Typical applications:- X-Ray Scanning: Food Inspection
- Fill Level Confirmation
- Security Applications
사양
(Ref. 128091-001 REV. L)
X-Ray Characteristics:
Tube Type: Glass tube, Tungsten target, Be filter
Focal Spot Options: 0.8mm x 0.8mm (IEC 336)
Beam Filter: 5052 Al, 0.040" (±0.01")
Beam Geometry: Asymmetrical fan 80° x 10° ±2°
Input Voltage:
200-264Vac, 50/60Hz, 4.0A max
X-Ray Tube Voltage:
Nominal X-Ray tube voltage is adjustable between 40kV to 80kV
X-Ray Tube Current:
0.5mA to 4mA over specified tube voltage range
X-Ray Tube Power:
320W maximum continuous
Voltage Regulation:
Line: ±0.05% for a ±10% input line change
Load: ±0.05% for a 0.5mA to 4mA load change
Voltage Accuracy:
Voltage measured across the X-Ray tube is within ±2% of the programmed value
Voltage Risetime:
Ramp time shall be <500ms from 10% to 90% of rated output
Voltage Overshoot:
Within 5% of rated voltage in <10ms
Voltage Ripple:
≤ 1% p-p of rated voltage @ 1kHz
Current Regulation:
Line: ±0.5% @ 50-100% V nominal over specified Line range
Load: ±0.5% @ 50-100% V nominal over specified Load range
Current Accuracy:
Current measured through the X-Ray tube is within ±2% of the programmed value
Current Risetime:
<500ms from 10% to 90% of rated output
Arc Intervention:
4 arcs in 10 seconds = shutdown
Filament Configuration:
Internal high frequency AC filament drive with closed loop filament emission control
Analog Interface:
0 to 10Vdc ground referenced monitoring signals
Digital Interface:
RS-232
Control Software:
A demo GUI for engineering evaluations will be provided for the RS-232 digital interface upon request.
Interlock Signals:
A hardware interlock functions in digital programming modes.
Operating Temperature:
0°C to +40°C
Storage Temperature:
-40°C to +70°C
Humidity:
10% to 90% relative humidity, non-condensing
Cooling:
Heat exchanger w/fan and oil pump
Input Line Connector:
Terminal block, Schurter, Inc. part no. 6100-33
Digital Interface Connector:
9 pin D, female
Analog Monitoring Connector:
10 pin Phoenix Contact 1755503
PIN SIGNAL PARAMETERS
1 Line 200-264Vac Input
2 GND 200-264Vac Input
3 Neutral Neutral
Grounding Point:
8-32 ground stud provided on chassis
Dimensions:
See outline drawing
Weight:
120lbs (54.4kg) maximum
Orientation:
Can be mounted in any orientation.
X-Ray Leakage:
Not to be greater than 0.5mR/hr at 5cm outside the external surface
Regulatory Approvals:
Designed to be compliant to EEC EMC
Directive and EEC Low Voltage Directive with an external filter.
AC INPUT POWERTERMINAL BLOCK
Pin | Signal | Parameters |
---|---|---|
1 | Line | Line |
2 | Line | Line |
3 | Line | Line |
4 | Neutral | Neutral |
5 | Neutral | Neutral |
6 | Neutral | Neutral |
RS-232 DIGITAL INTERFACE JB16 9 PIN FEMALE D CONNECTOR
Pin | Signal | Parameters |
---|---|---|
1 | N/C | No Connection |
2 | TX | RS-232 Transmit |
3 | RX | RS-232 Receive |
4 | N/C | No Connection |
5 | SGND | Signal Ground |
6 | N/C | No Connection |
7 | N/C | No Connection |
8 | N/C | No Connection |
9 | N/C | No Connection |
ANALOG MONITORING— JB11 10 PIN PHOENIX CONTACT
Pin | Signal | Parameters |
---|---|---|
1 | X-Ray Enable | +24Vdc = Enable X-Ray 0Vdc/Open = Disable X-Rays |
2 | RTN | Signal Return |
3 | N/C | No Connection |
4 | kV Monitor | 0 to 10Vdc = 0 to 100kV, Zout = 10kΩ |
5 | SGND | Signal Return |
6 | mA Monitor | 0 to 10Vdc = 0 to 5mA, Zout = 10kΩ |
7 | Fault | Open Collector, High (Open) = No Fault, 35Vdc @10mA max. |
8 | HV On Lamp, Relay N/O | Relay Normally Open, 50Vdc @ 1A maximum |
9 | HV On Lamp, Relay Common | Relay Common, 50Vdc @ 1A maximum |
10 | HV On Lamp, Relay N/C | Relay Normally Closed, 50Vdc @ 1A maximum |
테이블 및 다이어그램
DIMENSIONS: in.[mm]
TOP VIEW
SIDE VIEW
BACK VIEW
Frequently Asked Questions
Why Is Oil Insulation Used?
Do I Need to Ensure My Monoblock® Stays Cool? Why?
How Often Do I Need to Season My Monoblock® X-Ray Source? Why?
Application Notes AN-12 – The Benefit of Using a Current Source to Power X-Ray Tube Filament Circuits