1.8 - 6kW 工业级 X 射线发生器
斯派曼XRV 系列X 射线高压电源为紧凑型1.8kW 至6.0kW,为高性能X 射线检查发生器树立标准。输出电压范围为160kV至450kV,有负极性、正极性或双极输出配置,这款型号几乎可用于各种应用需求。
有源的功率因数校正电路降低了输入电流的需求,同时将线路相关的EMI 减到最少。斯派曼专有的逆变器拓扑技术可以实现前所未有的效率和功率密度。固态封装高压部分进一步减少了电源的体积和重量,并提供了可靠的、免维护运行。
DSP 基于SMT 控制电路,USB、以太网和RS-232 连同模拟接口供您选择,简化了OEM 系统的集成。两路直流输出、通过复杂的发射电流调节电路控制调节灯丝电源,来提供精确的和稳定的X 射线管电流。全面的故障诊断电路、电弧感应、电弧灭弧和电弧计数功能都成为紧凑的/节省空间的X 射线发生器的一部分。
规格
(Ref. 128060-001 REV. W)
Typical Applications
Non Destructive TestingX-Ray Scanning
Security Applications
Medical Applications
Options
400Vac ±10% (6kW only)
GUI Control Software for XRV
XRVC (XRV Controller)
Specifications
Input Voltage:
1.8kW, 3.0kW, 4.0kW and 4.5kW models:
180-264Vac, single phase, 47-63 Hertz, active power factor corrected input to ≥0.98
6.0kW models:
208 or 400Vac, ±10%, three phase, 47-63 Hertz, passive power factor corrected
Input Current:
1.8kW, 3.0kW, 4.0kW and 4.5kW models: <30 amps
6.0kW models: <25 amps per phase
Output Voltage:
Accuracy: 0.25%
Stability: ≤ 0.1% per 8 hours, after 1 hour warm up
1.8kW, 3.0kW, 4.0kW and 4.5kW models:
Load:±0.05% of rated output voltage for a full load change
Line: ±0.05% of rated output voltage over specified input voltage range
6.0kW models:
Load:±0.1% of rated output voltage for a full load change
Line: ±0.1% of rated output voltage over specified input voltage range
Output Polarity:
See “model selection” table
Output Current:
See “model selection” table
Ripple:
See “model selection” table
Temperature Coefficient:
1.8kW, 3.0kW, 4.0kW and 4.5kW models:
50ppm/°C
6.0kW models:
±50ppm/°C
Emission Current:
Accuracy: 0.25%
Stability: 100ppm/°C
1.8kW, 3.0kW, 4.0kW and 4.5kW models:
Load: ±0.05% of rated output current for a change from 30% to 100% of rated output voltage
Line: ±0.05% of rated output current over specified input voltage range
6.0kW models:
Load: ±0.1% of rated output current for a change from 30% to 100% of rated output voltage
Line: ±0.1% of rated output current over specified input voltage range
Filament:
Output:
0-6 amps at a compliance of 10Vdc, maximum
Dual Focal Spot:
Small and large, selectable via interface signal
Configuration:
DC filament drive. Closed loop emission control regulates filament setting to provide desired X-Ray tube emission current
Control Interface:
Remote Interface:
Analog, USB, Ethernet and RS-232 are standard
Control Software:
A VB GUI is provided for RS-232/USB, the Ethernet interface has an embedded applet for control (see page 2)
Operating Temperature
0°C to +50°C
Storage Temperature:
-40°C to +85°C
Humidity:
20% to 85% RH, non-condensing
Mains Input Connector:
1.8kW, 3.0kW, 4.0kW and 4.5kW models:
Type 97-3102A-24-11P
6.0kW models:
Type 97-3102A-24-22P
Interface Connectors:
Digital—Ethernet, RS-232 and USB
Analog—25 pin connector
Output Connector:
See “model selection” table
Cooling:
Forced air
Regulatory Approvals:
Compliant to EEC EMC Directive/Compliant to EEC Low Voltage Directive, all but 6000 watt unit. NFC 74-100 compliant. UL/CUL recognized, File E227588, all but 6000 watt unit. RoHS Compliant.
Options
400Vac ±10% (6kW only)
GUI Control Software for XRV
The GUI is specifically designed for controlling XRV series power supplies. As an alternative to the analog control, the GUI will allow the user to control all necessary functions of the HVPS from a user-friendly windows based menu. Additionally the GUI can be use as a diagnostic tool when the HVPS is controlled via the analog interface.
XRV160/320/350 SPECIFICATIONS
XRV160*1800 | XRV160*3000 | XRV160*4000 | XRV160*6000 | XRV320P&N1800 | XRV320P&N4500 | XRV350P&N4500 | |
---|---|---|---|---|---|---|---|
DC Output Voltage | 0 to 160kV | 0 to 160kV | 0 to 160kV | 0 to 160kV | 0 to ±160kV | 0 to ±160kV | 0 to ±175kV |
Polarity* | Pos or Neg | Pos or Neg | Pos or Neg | Pos or Neg | Bipolar | Bipolar | Bipolar |
Output Rated Current | 0-30mA | 0-30mA | 0-50mA | 0-50mA | 0-30mA | 0-30mA | 0-30mA |
Output Power | 1.8kW | 3.0kW | 4.0kW | 6.0kW | 1.8kW | 4.5kW | 4.5kW |
Ripple/Noise (p-p) | <0.025% | <0.05% | <0.1% | <0.25% | <0.025% | <0.1% | <0.1% |
Dimensions | 10.09˝ H x 17.16˝ W x 24˝ D (256mm x 436mm x 609mm) | 2 x (10.09˝ H x 17.16˝ W x 24˝ D) (256mm x 436mm x 609mm) | |||||
Weight | 150 lbs. (68kg) | 150 lbs. (68kg) | 150 lbs. (68kg) | 155 lbs. (70.3kg) | 300 lbs. (136 kg) | 300 lbs. (136 kg) | 300 lbs. (136 kg) |
Output Connector | R24 | R24 | R24 | R24 | Two R24 | Two R24 | Two R24 |
XRV225/450 SPECIFICATIONS
XRV225*1800 | XRV225*3000 | XRV225*4000 | XRV450P&N1800 | XRV450P&N4500 | |
---|---|---|---|---|---|
DC Output Voltage | 0 to 225kV | 0 to 225kV | 0 to 225kV | 0 to ±225kV | 0 to ±225kV |
Polarity* | Pos or Neg | Pos or Neg | Pos or Neg | Bipolar | Bipolar |
Output Rated Current | 0-30mA | 0-30mA | 0-30mA | 0-30mA | 0-30mA |
Output Power | 1.8kW | 3.0kW | 4.0kW | 1.8kW | 4.5kW |
Ripple/Noise (p-p) | <0.025% | <0.05% | <0.1% | <0.025% | <0.1% |
Dimensions | 15.90˝ H x 17˝ W x 30.72˝ D (404mm x 432mm x 780mm) | 2 x (15.90˝ H x 17˝ W x 30.72˝ D) (404mm x 432mm x 780mm) | |||
Weight | 240 lbs. (109kg) | 240 lbs. (109kg) | 240 lbs. (109kg) | 480 lbs. (218 kg) | 480 lbs. (218 kg) |
Output Connector | R28** | R28** | R28** | Two R28** | Two R28** |
Units are available in positive output polarity without filament, see model selection table for ordering details.
*Specify “P” for positive or “N” for negative polarity.
**Order SHV HV cable flange p/n 407141-024 if using Comet HV cable with R28SL spring loaded plug.
Pin | Signal | Parameters |
---|---|---|
C | HV Output | XRV160 and XRV320—R24 Connector XRV225 and XRV450—R28 Connector |
S | Small Filament Output | 0 to 6 amps @ 10Vdc |
L | Large Filament Output | 0 to 6 amps @ 10Vdc |
J2 ANALOG INTERFACE—25 PIN D CONNECTOR
Pin | Signal | Parameters |
---|---|---|
1 | Power Supply Fault | Low, sum of faults, HVPS detected a fault, open collector, 50V @ 10mA max |
2 | mA Program | 0 to 10V FS Z in = 10M ohms |
3 | kV Program | 0 to 10V FS Z in = 10M ohms |
4 | Filament Limit L/S Ref.* | 0 to 10V FS Z in = 10M ohms |
5 | Filament Preheat L/S Ref.* | 0 to 10V FS Z in = 10M ohms |
6 | kV Monitor | 0 to 10V FS Z out = 4.99k ohms |
7 | mA Monitor | 0 to 10V FS Z out = 4.99k ohms |
8 | Filament Current Monitor* | 0 to 10V FS Z out = 4.99k ohms |
9 | Signal Ground | Ground |
10 | X-Ray Enable | +24Vdc = X-Ray ON, connect to pin 14 with dry contact relay |
11 | Filament ON* | Filament ON status, low, filament is ON open collector 50V, @ 10mA max |
12 | Interlock 1 | Active low, interlock is closed, safe to enable HV |
13 | Interlock 2 | Active low, interlock is closed, safe to enable HV |
14 | +24Vdc | +24Vdc @ 100mA, maximum |
15 | Filament Enable* | Active low, turn filament ON |
16 | Filament Control* | Active low, filament is regulated by ECR (HV must be ON). Not active, the filament is regulated by the preheat reference |
17 | Filament L/S Select | Filament selection large or small, low = small spot is selected |
18 | Filament L/S Confirm | Open collector, 50V @ 10mA max Filament selection confirm, low = small spot is selected |
19 | HVPS RDY | Low = HVPS ready, open collector, 50V @ 10mA max |
20 | X-Ray ON | X-Ray ON status, low = X-Rays are ON open collector, 50V @ 10mA max |
21 | Interlock Status | Low, interlocks are closed, can enable HV open collector, 50V @ 10mA max |
22 | GND | Digital ground |
23 | X-Ray ON Pre-Warn | Pre-warning, low, before X-Ray ON open collector, 50V @ 10mA max |
24 | Reset | Active low, minimum 10mS transition |
25 | Arc fault | Low, arc fault, the HVPS has detected an arc open collector, 50V @ 10mA max |
*Not active on positive models
MODEL SELECTION TABLE
Model | Voltage | Power | Polarity |
---|---|---|---|
XRV160*1800 | 160kV | 1.8kW | Pos or Neg |
XRV160*3000 | 160kV | 3.0kW | Pos or Neg |
XRV160*4000 | 160kV | 4.0kW | Pos or Neg |
XRV160*6000/208V | 160kV | 6.0kW | Pos or Neg |
XRV160*6000/400V | 160kV | 6.0kW | Pos or Neg |
XRV225*1800 | 225kV | 1.8kW | Pos or Neg |
XRV225*3000 | 225kV | 3.0kW | Pos or Neg |
XRV225*4000 | 225kV | 4.0kW | Pos or Neg |
XRV225*6000/208V | 225kV | 6.0kW | Pos or Neg |
XRV225*6000/400V | 225kV | 6.0kW | Pos or Neg |
XRV320P&N1800 | ±160kV | 1.8kW | Bipolar |
XRV320P&N4500 | ±160kV | 4.5kW | Bipolar |
XRV350P&N4500 | ±175kV | 4.5kW | Bipolar |
XRV450P&N1800 | ±225kV | 1.8kW | Bipolar |
XRV450P&N4500 | ±225kV | 4.5kW | Bipolar |
*Specify “P” for positive or “N” for negative polarity. Positive polarity models do not have
integrated filament power supplies. Contact Spellman for custom output voltage/power models.
RS-232 DIGITAL INTERFACE—J3 9 PIN FEMALE D CONNECTOR
Pin | Signal | Parameters |
---|---|---|
1 | N/C | No Connection |
2 | TX out | Receive Data |
3 | RX in | Transmit Data |
4 | N/C | No Connection |
5 | SGND | Ground |
6 | N/C | No Connection |
7 | N/C | No Connection |
8 | N/C | No Connection |
9 | N/C | No Connection |
ETHERNET DIGITAL INTERFACE—J4 8 PIN RJ45 CONNECTOR
Pin | Signal | Parameters |
---|---|---|
1 | VBUS | +5 Vdc |
2 | D- | Data - |
3 | D+ | Data + |
4 | GND | Ground |
JB1 MAIN AND AUXILIARY INPUT POWER—TYPE 97-3102A-24-11P (Single Phase Units)
Pin | Signal | Parameters |
---|---|---|
A | Auxiliary AC Line Power | 180-264Vac |
B | Auxiliary Ground | Ground |
C | Auxiliary AC Neutral | Neutral |
D | Main AC Line Power | 180-264Vac |
E | Main Ground | Ground |
F | Main AC Neutral | Neutral |
JB1 MAIN AC INPUT POWER—TYPE 97-3102A-24-22P (Three Phase Units)
Pin | Signal | Parameters |
---|---|---|
A | Line 1 | 208Vac, ±10%, 50/60Hz @ 25 amps |
B | Line 2 | 208Vac, ±10%, 50/60Hz @ 25 amps |
C | Line 3 | 208Vac, ±10%, 50/60Hz @ 25 amps |
D | GND | Ground |
Note: Use 4 conductor cable or single isolated wires rated no
less that 600Vac, 30 amps (10AWG, minimum)
JB2 AUXILIARY AC INPUT POWER—TYPE 97-3102A-20-3P (Three Phase Units)
Pin | Signal | Parameters |
---|---|---|
A | Line 1 | 208Vac, ±10%, 50/60Hz (source 3 phase L1, L2) |
B | Line 2 | 208Vac, ±10%, 50/60Hz (source 3 phase L1, L2) |
C | GND | Ground |
System Ground: System ground wires (10AWG minimum) to
the ground terminal E1 GND to the power supply using ground
stud M6 X 20MM, with M6 nut.
表和图
DIMENSIONS: in.[mm]
XRV160
TOP VIEW
FRONT VIEW
REAR VIEW
XRV225
TOP VIEW
FRONT VIEW
REAR VIEW
Note: All specifications are subject to change without notice. Please consult the PDF version of this datasheet for the most up-to-date revision.